June 2, 1994...Butte, Montana

Note: This article has been revised since origianlly written. At that time it referred primarily to the use of the STS system. Today it refers mainly to the Fine-Cut Endo Contra Angle but since the motion is that same, it still holds true for the STS system.

Visualize yourself scrubbing the inside of a tapered beer glass with straight bottle brush.

Each stroke of the brush is straight in and straight out but in a different place against the circumference of the glass.

Here's a copy of some links from the Indian Dental Organization.

Circumferential Filing Video - circum filing.mpg Click here
This video shows circumferential filing being done on a clear plastic block. The Fine Cut Endo Contra-Angle is being used with a Fine Cut File (Positive rake angle). The handpiece moves the file up and down with a stroke length slightly greater than the interflute distance. The file is moved around the circumference of the canal thereby enlarging the canal.
Circumferential Filing Second Video - circum filing two.mpg Click here
This video shows the filing being done with a view from the top. The movement of the file around the circumference of the canal can be clearly seen.
Washed Field Video Part I- washed field 1a.wmv Click here
This video demonstrates the washed field technique. A drop of Caries Indicator is introduced in the canal space. Observe how the dye clearly outlines the root canal space. Initially the file in introduced and a cirucumferential motion is used but without any water. It can be noted that none of the dye moves out of the canal space. Any debris that will be created due to the filing action will collect in the canal and tend to clog the space. Now observe as a very small and intermittent stream of water is directed. Even an intermittent stream of water recylces the entire liquid in the root canal in less than 10 seconds. This also flushes out all the debris. Also note that none of the liquid gets pushed past the apex which has been made patent.
In the next video observe how a forceful copious flow of water recylces the entire liquid in 2 to 3 seconds.
Washed Field Video Part II - washed field 2.wmv Click here
This video is a repeat demonstration of the washed field technique demonstrating how the liquid with all the debris gets pumped out of the coronal end in a matter of 2 to 3 seconds when the flow of water is continuous and copious.

The root canal is tapered and the only access you have to it is from the top, like the glass.

The instruments are essentially the same as the bottle brush.

The motion is essentially the same.

This motion is known as linear oscillation.

The length of the stroke must be at least as long as the distance between the flutes.

Or to put it in technical language the amplitude of the stroke must be greater than the inter-flute distance.

With Fine-Cut Files those flutes are very close together and so the up and down stroke can be very small.

Almost not a stroke at all but more of a jiggle.

With the Fine-Cut Endo Handpiece this stroke is minimal...usually about a millimeter.

Theoretically when a file has been pre-curved, the up and down motion should be a curved up and down motion, but is a little silly talking about an arc of less than a millimeter and so we just say jiggle up and down.

But, because the stroke is so small, it is almost irrelevant to talk about doing anything different in curved canals than in straight canals.

You must understand that most sonic and ultrasonic systems do not and cannot move the file up and down in the canal.

In fact most move the file in a waggling motion, that is, the tip is moved back and forth, not in and out.

If, in fact, the ultrasonic had any cutting action at all it would be dangerous because the waggling would cause a ledge to form at the tip of the file.

The only function of most of these units is to keep the file cutting smoothly like a vibrating sander keeps the sanding block from skipping and gouging.

The cutting must be done by YOU moving the file in and out of the canal.

It is essential for circumferential filing for the file to fit loosely in the canal.

As each circumnavigation of the canal is made, the canal gets slightly larger.

When it is large enough for the next file to fit loosely, the next larger file is used.

And thus through the sizes until either the canal is clean enough or the canal is large enough.

Each file is used in each canal for about 20-30 seconds depending on:

Thus usually a canal can be enlarged with a total time of less than 3-4 minutes.

And since in a molar the proportion of time devoted to changing files is less, the average per canal is slightly less.

Usually it takes about 5-10 minutes to prepare a molar.

With the Fine-Cut Endo Handpiece the frequency of the stroke can exceed 350 per second(22,000 rpm), this process is materially accelerated.

You should note that it is almost impossible to do circumferential filing with

Since you can only apply as much pressure as the strength and flexibility of the file allow, you must have a positive rake instrument which cuts with the slightest touch.

You cannot apply enough pressure laterally to get a negative rake instrument to cut.

They must be wedged in, such as in PQTP or Balanced Force Filing, which produce lateral force as a function of the force vectors of the downward pressure.

No Ledges

One of the advantages of circumferential filing is that is causes NO LEDGES.

Ledges can only be caused by an end cutting instrument that cuts inward from the crown down to the apex.

Since in circumferential filing the file is passed to depth with no resistance and the cutting is upward, it will in fact erase any ledges it might encounter, not create them.

The end result of a canal prepared with circumferential filing is a canal that is hyperbolic in shape, that is the angle between the walls gets greater as you get further from the apex i.e.

trumpet shaped.

This is the ideal shape for condensing gutta percha and also incidentally for filling with cement...that of a gradually decreasing diameter going toward the apex.

In the electronic web page course Automated Endo, there is a description and an animated GIF that explains this.

In fact it explains two different approaches to filing, named "X"-filing

and "V"-filing.

One of the unique features of circumferential filing is that it maintains the basic shape of the canal.

That is, if the canal is round it keeps it round, just a little larger.

If it is ovoid, ribbon-shaped or kidney shaped the canal ends up bigger but still ovoid, ribbon-shaped or kidney shaped.

This is of absolutely no concern to those of us who fill with cement because the cement always assumes the shape of the canal at the extrusion point of the syringe.

If you are planning on filling with gutta percha and the canal is anything but round, the smaller dimension of the canal may be too small to get your pluggers in and it may be necessary to use smaller pluggers or to over-enlarge the canals to accommodate the larger pluggers to avoid splitting the root.

This problem does not occur in syringe endodontics.

(see also Crown-Down Prepping) (see also orifice opening)

E-mail your comments to drjack@BetterEndo.com